Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Trauma Emerg Surg ; 49(1): 155-163, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35879617

RESUMO

BACKGROUND AND PURPOSE: A tendon-sparing modification of the posterior approach to the hip joint was introduced in the specialist hip unit at our institution in 2016. The SPAIRE technique-acronym for "Saving Piriformis And Internus, Repair of Externus" preserves the insertions of gemellus inferior, obturator internus, gemellus superior and piriformis intact. We compare the results of the first 285 hip hemiarthroplasty patients, unselected but preferentially treated by our hip unit surgeons using the SPAIRE technique, with 567 patients treated by all orthopaedic surgeons (including the hip unit) in the department over the same 3.5 year period using the standard lateral approach. We report length of stay, return to pre-injury level of mobility, place of residence and mortality at 120 days. PATIENTS AND METHODS: The review included all hemiarthroplasty patients. Pre-fracture mobility and place of residence, surgical approach, grade of senior surgeon in theatre, stem modularity, acute and overall length of stay, mobility, place of residence, re-operations and mortality at 120 days were recorded. Data were obtained from the National Hip Fracture Database that included a telephone follow-up at 120 days and from electronic patient records. RESULTS: The odds of returning to pre-injury level of mobility were higher in the SPAIRE technique group than in the standard lateral group; adjusted odds ratio (95% confidence interval (CI)) 1.7 (1.1 to 2.7, p = 0.01). INTERPRETATION: When used in hip hemiarthroplasty, the SPAIRE technique appears safe and may confer benefit in maintaining the pre-injury level of mobility over the standard lateral approach.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Fraturas do Quadril , Humanos , Hemiartroplastia/métodos , Fraturas do Quadril/cirurgia , Músculo Esquelético/cirurgia , Artroplastia de Quadril/métodos , Fraturas do Colo Femoral/cirurgia , Resultado do Tratamento
2.
Trials ; 23(1): 924, 2022 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-36335403

RESUMO

BACKGROUND: The HemiSPAIRE trial is being conducted to determine whether a modified muscle sparing technique (SPAIRE-"Save Piriformis and Internus, Repairing Externus") in hip hemiarthroplasty brings clinical benefits compared to the standard lateral technique in adults aged 60 years or older, with a displaced intracapsular hip fracture. This article describes the detailed statistical analysis plan for the trial.  METHODS AND DESIGN: HemiSPAIRE is a definitive, pragmatic, superiority, multicentre, randomised controlled trial (with internal pilot) with two parallel groups. Participants, ward staff and all research staff involved in post-operative assessments are blinded to allocation. This article describes in detail (1) the primary and secondary outcomes; (2) the statistical analysis principles, including a survivor average causal effect (SACE) method chosen specifically to address the issue of potential bias from differential survival between trial arms, which was seen from data review by the Trial Steering Committee, the participants that will be included in each analysis, the covariates that will be included in each analysis, and how the results will be presented; (3) planned main analysis of the primary outcome; (4) planned analyses of the secondary outcomes; and (5) planned additional analyses of the primary and secondary outcomes. TRIAL REGISTRATION: ClinicalTrials.gov NCT04095611. Registered on 19 September 2019.


Assuntos
Artroplastia de Quadril , Hemiartroplastia , Fraturas do Quadril , Adulto , Humanos , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Fraturas do Quadril/cirurgia , Artroplastia de Quadril/métodos , Quadril/cirurgia , Músculos/cirurgia , Resultado do Tratamento
3.
J Arthroplasty ; 34(7S): S297-S301, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31000404

RESUMO

BACKGROUND: Cement-in-cement femoral revision is a proven technique in revision total hip arthroplasty, with excellent results reported using standard-sized Exeter stems. The Exeter 44/00/125 short revision stem was introduced in 2004 to facilitate cement-in-cement revision. The stem is 25-mm shorter and has a slimmer body than standard stems to facilitate adjustment of depth of insertion and stem version. It is not known if this change in stem size affects its long-term performance. We therefore reviewed the outcome of all Exeter short revision stems used for cement-in-cement revision in our unit, with a minimum of 5 years of follow-up. METHOD: One hundred sixty-six cases were performed between 2004 and 2010. Mean follow-up of surviving patients was 8.1 years (range 5.0-11.7). The fate of all 166 hips were known and included in the survival analysis. RESULTS: Median clinical scores improved significantly. Sixteen hips required re-revision (infection 6, loose cup 3, periprosthetic fracture 3, instability 2, stem fracture with chronic infection 1, and pain 1). Kaplan-Meier survival analysis at 10 years revealed 100% survival for aseptic stem loosening, 96.8% survival for stem failure, and 88.9% survival for all causes. CONCLUSION: The Exeter short revision stem performed as well as standard length stems for cement-in-cement revision in this the largest and longest review of their use. Larger registry-based studies may provide additional information on the performance of this stem.


Assuntos
Cimentos Ósseos , Prótese de Quadril , Reoperação/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Feminino , Fêmur/cirurgia , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Dor/cirurgia , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Análise de Sobrevida
4.
Hip Int ; 26(1): e1-3, 2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26692247

RESUMO

We describe a challenging femoral revision for aseptic loosening in a relatively young and active man. The femur had gross osteolysis, an absent calcar and a cortical diaphyseal defect at the level of the isthmus (Paprosky 3b defect). The cortical defects were repaired and the whole femur then restored with Femoral Impaction Grafting (FIG) using custom-made impaction instruments and an anatomic shaped collarless, polished, tapered femoral component.In the active adult, bone restoring revision techniques such as impaction grafting should be considered to give a realistic prospect of host bone augmentation rather than simply aiming for a distally fixed stem in a patulous femoral canal.


Assuntos
Artroplastia de Quadril/instrumentação , Transplante Ósseo , Prótese de Quadril , Osteólise/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação
5.
Proc Inst Mech Eng H ; 227(5): 503-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23637260

RESUMO

When proximal bone stock is compromised at revision hip arthroplasty, distal fixation is often relied upon for stability of the femoral component. In such circumstances, torsional forces can result in debonding and loosening. This study compared the torsional behaviour of a cemented, polished and featureless (plain) stem with cemented, polished stems featuring fins or flutes. The finned stem construct was found to be significantly stiffer than the fluted stem. The maximum torque of the finned and fluted stems was significantly higher than the plain stem, with no difference between the finned and fluted stems. Distal stem features may provide a more reliable and greater resistance to torque in polished, cemented revision hip stems. Finned stem features may also increase the stiffness of the construct.


Assuntos
Cimentação/métodos , Cabeça do Fêmur/fisiologia , Prótese de Quadril , Adesividade , Análise de Falha de Equipamento , Cabeça do Fêmur/cirurgia , Fricção , Desenho de Prótese , Estresse Mecânico , Resistência à Tração , Torque
6.
J Bone Joint Surg Am ; 95(2): 168-74, 2013 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-23324965

RESUMO

BACKGROUND: The use of cementless acetabular components in total hip arthroplasty has gained popularity over the past decade. Most total hip arthroplasties being performed in North America currently use cementless acetabular components. The objective of this systematic review and meta-analysis was to compare the survivorship and revision rate of cemented and cementless acetabular components utilized in total hip arthroplasty. METHODS: A primary literature search in PubMed identified 3488 articles, of which 3407 did not meet the inclusion criteria and were excluded. Only English-language articles on either the survivorship or revision rate of primary total hip arthroplasty at a minimum of ten years of follow-up were included. The present study analyzed forty-five articles reporting the long-term outcome of cementless acetabular components, twenty-nine reporting the outcome of cemented acetabular components, and seven comparing cemented and cementless acetabular components. Meta-analysis (with a random-effects model) was performed on the data from the seven comparative studies, and study-level logistic regression analysis (with a quasibinomial model) was performed on the pooled data on the eighty-one included articles to determine a consensus. The studies were weighted according to the number of total hip arthroplasties performed. RESULTS: The meta-analysis did not reveal any effect of the type of acetabular component fixation on either survivorship or revision rate. The regression analysis revealed the estimated odds ratio for survivorship of a cemented acetabular component to be 1.60 (95% confidence interval, 1.32 to 2.40; p = 0.002) when adjustments for factors including age, sex, and mean duration of follow-up were made. CONCLUSIONS: The preference for cementless acetabular components on the basis of improved survivorship is not supported by the published evidence. Although concerns regarding aseptic loosening of cemented acetabular components may have led North American surgeons toward the nearly exclusive use of cementless acetabular components, the available literature suggests that the fixation of cemented acetabular components is more reliable than that of cementless components beyond the first postoperative decade.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Cimentação , Humanos , Modelos Logísticos , América do Norte , Complicações Pós-Operatórias , Falha de Prótese , Reoperação
7.
Clin Orthop Relat Res ; 466(2): 324-31, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18196413

RESUMO

UNLABELLED: The Exeter Universal hip (Stryker Inc., Newbury, UK) has reported survival rates of 91.74% at 12 years in all patients with reoperation as an endpoint. However, its performance in younger patients has not been fully established. We reviewed survivorship and the clinical and radiographic outcomes of this hip system implanted in 107 patients (130 hips) 50 years old or younger at the time of surgery. The mean age at surgery was 42 years. The minimum followup was 10 years (mean, 12.5 years; range, 10-17 years) with no patients lost to followup. Twelve hips had been revised. Of these, nine had aseptic loosening of the acetabular component and one cup was revised for focal lysis and pain. One hip was revised for recurrent dislocation and one joint underwent revision for infection. Radiographs demonstrated 14 (12.8%) of the remaining acetabular prostheses were loose but no femoral components were loose. Survivorship of both stem and cup from all causes was 92.6% at an average of 12.5 years. Survivorship of the stem from all causes was 99% and no stem was revised for aseptic loosening. The Exeter Universal stem performed well, even in the young, high-demand patient. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Adulto , Fatores Etários , Artrite Infecciosa/diagnóstico por imagem , Artrite Infecciosa/cirurgia , Artroplastia de Quadril/efeitos adversos , Avaliação da Deficiência , Feminino , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Falha de Prótese , Radiografia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...